An acrylic gel is applied to substrates that have been either cleaned prior to coating or assembled with low residue “no clean” materials. Users should perform adequate testing to confirm compatibility between the coating and their particular assembly materials, process conditions and cleanliness level. Please contact your HumiSeal® representative for additional information.
Syringe Application
HumiSeal® Acrylic Gel is intended for automated needle dispensing, but may also be applied manually.
|
0.95 ± 0.02 g/cm3 |
|
699 grams/litre |
|
≤ 3mm |
|
10 min @ 80°C |
- Recommended Curing Conditions
|
3 hrs @ 80°C |
- Time Required to Reach Optimum Properties
|
7 days |
|
HumiSeal® Stripper 1080, 1080EU |
- Shelf Life at Room Temperature, DOM
|
12 months |
- Dissipation Factor, at 1MHz and 25°C, per ASTM D150-98
|
0.01 |
- Insulation Resistance, per MIL-I-46058C
|
5.5 x 1014 ohms (550TΩ) |
- Moisture Insulation Resistance, per MIL-I-46058C
|
7.0 x 1010 ohms (70GΩ) |